MSM huge rollouts are stalling | Community
Skip to main content
harishmallineni
New Participant
Nov 26, 2019 10:55 AM UTC
Solved

MSM huge rollouts are stalling

en-us is the blueprint for en-ca & en-gb having 'push on modify' rollout config. And within en-us we have another blueprint, say internal blueprint, which has 3000 live-copy pages. Now the problem is when the author tries to rollout a component from the internal blueprint to all 3000 pages from classic UI the process is being stalled(with red lights). Any idea what is causing the issue?

AEM version : 6.3.2

This post is no longer active and is closed to new replies. Need help? Start a new post to ask your question.
user05162Accepted solution
Employee
Nov 26, 2019 3:24 PM UTC

Can you enable DEBUG level for the logger com.day.cq.wcm.msm in /system/console/slinglog , and repeat the problematic MSM Action?

That should give you some information on why the process is stalling.

Also, check the CPU usage and Memory consumption during this process.

2 replies

harishmallineni
New Participant
Nov 26, 2019 4:11 PM UTC

thank you.

Translate
user05162Accepted solution
Employee
Nov 26, 2019 3:24 PM UTC

Can you enable DEBUG level for the logger com.day.cq.wcm.msm in /system/console/slinglog , and repeat the problematic MSM Action?

That should give you some information on why the process is stalling.

Also, check the CPU usage and Memory consumption during this process.